屋顶方案的矩形双搭接屋面(标准模式)
屋檐:矩形双搭接屋面(标准模式)
斜脊:矩形双搭接屋面(标准模式),一半粘结
斜脊:矩形双搭接屋面(标准模式),与非标准屋面石板石头一半的粘结。
斜脊:矩形双圈屋面(标准模式),基石
脊:矩形双圈屋面(标准模式)
主谷:矩形双圈屋面与螺柱谷(标准模式)
Material requirements planning
Rectangular double lap roofing (standard pattern)
Stone format:
Rectangular double lap roofing (standard pattern) with squares
Height and width cm
approx. kg/1000 slates
Rectangular double cladding at the wall
Underlay Generally the "References for Claddings for External Walls ventilated at Rear" ["Hinweise für hinterlüftete Au?enwandbekleidungen"] apply to the underlay including the base structure.
In case of claddings for external walls not ventilated at rear they shall be logically applied as far as the joints and fasteners are concerned.
Fastening The slates are fastened:
- in case of concealed nailing with 2 and/or 3 corrosion-proof slate fixing nails or pins - in case of using cramps with 1 or 2 cramps of rust-proof steel, material number 1.4571 or copper - in case of concealed nailing and additional use of cramps with 2 corrosion-proof slate fixing nails or pins and one cramp or hook of rust-proof steel or copper
- in case of concealed nailing with 2 and/or 3 corrosion-proof slate fixing nails or pins
- in case of using cramps with 1 or 2 cramps of rust-proof steel, material number 1.4571 or copper
- in case of concealed nailing and additional use of cramps with 2 corrosion-proof slate fixing nails or pins and one cramp or hook of rust-proof steel or copper
To the extent the cladding is made on battens with cramp hooks approximately 10% of the calculated required quantity of the hooks are needed in the form of drive-in hooks on account of the crossing points of battens and counter-battens.
Material requirements for wall surfacing in rectangular claddings with hook fastening rectangular double cladding (upright format), octagones and coquettes
Measurements and quantities per m2 nailing
Rectangular overlap cladding
Partitioning of out of the straight walls
Exemple
Joint spacing :
Since 12.623 is less than 12.7, take the next lower integral number: 84
The vertical linings out are applied in the distance of
above:
below:
The levelling is carried out via the joint.
Open slating
Only permitted on wall surfaces!
Table of material requirements for wall claddings in open slating with hook fastening, upright format and octagones
Rounded to 51 pieces
The vertical lining outs are carried out in a distance of above:
The levelling is effected by additional overlap.
Note:
Any projecting ends shall be taken into account when partitioning.
Material requirements planning (open slating)
Example of calculation:
Sidelap:
* corresponds to the space between battens
Horizontal cladding
Material requirements for wall claddings in horizontal cladding
Head and sidelap 40 mm (nailed)
30/20
Headlap:
Minimum overlaps on the roof
Rectangular double lap roofing (standard pattern) - Height depending on the roof pitch
Minimum overlaps on the wall
Rectangular slating
20 overlapped
60 overlapped
Horizontal slating